View Issue Details

IDProjectCategoryView StatusLast Update
0000142OpenMPTFile Format Supportpublic2011-06-10 23:51
ReporterSaga Musix Assigned ToSaga Musix  
PrioritynormalSeveritycrashReproducibilityalways
Status resolvedResolutionfixed 
Product VersionOpenMPT 1.19.02.00 (upgrade first) 
Target VersionOpenMPT 1.19.03.00 (upgrade first)Fixed in VersionOpenMPT 1.19.03.00 (upgrade first) 
Summary0000142: Saving IT instruments with invalid sample map crashes OpenMPT
Description

Saving an IT instrument (either stand-alone or in an IT module) which has a sample number in the sample map that is higher than the maximum sample number in the module will crash OpenMPT.

Steps To Reproduce

Create an instrument and assign a sample that does not exist to it, save IT file, watch OpenMPT crash.

TagsNo tags attached.
Has the bug occurred in previous versions?No. Revision 860 introduced this,
Tested code revision (in case you know it)

Activities

Saga Musix

Saga Musix

2011-06-10 23:51

administrator   ~0000212

Revision 896 / OpenMPT 1.19.02.05 fixes this.

Issue History

Date Modified Username Field Change
2011-06-10 23:50 Saga Musix New Issue
2011-06-10 23:50 Saga Musix Status new => assigned
2011-06-10 23:50 Saga Musix Assigned To => Saga Musix
2011-06-10 23:51 Saga Musix Note Added: 0000212
2011-06-10 23:51 Saga Musix Status assigned => resolved
2011-06-10 23:51 Saga Musix Fixed in Version => OpenMPT 1.19.02.* (old testing)
2011-06-10 23:51 Saga Musix Resolution open => fixed